TST‑C1032S Upper Hinge Flip‑Door Slamming Tester
The Upper‑Hinge Flip‑Door Slamming Tester simula ...
The Mattress Formaldehyde Gas Collection Tester is mainly applied to test the emission of formaldehyde and other volatile gases from mattresses.
GB 35607‑2017 《Green Product Assessment — Furniture》
| No. | Item | Specification |
|---|---|---|
| 1 | Operating temperature | 36±1 ℃ |
| 2 | Temperature uniformity | Temperature difference between any two measuring points ≤0.5 ℃ |
| 3 | Internal dimension of test chamber | 1300 mm(L) ×770 mm(W) ×300 mm(H) |
| 4 | External dimension of test chamber | 1100 mm(L) ×1100 mm(W) ×380 mm(H) |
| 5 | Test chamber | Interior: 304 mirror‑finished stainless steel, integral welding. Weld seams and surrounding areas are polished without deformation. All edges and corners are rounded. No rubber or adhesive materials that may interfere with testing. Sealing materials and other components exposed to chamber air do not adsorb organic substances and formaldehyde. |
| 6 | Insulation jacket | External insulation thickness: 10 mm |
| 7 | Inlet check valve | Four check valves (inner diameter Φ10 mm) mounted 50 mm from bottom on four side walls of chamber, for air replenishment |
| 8 | Exhaust check valve | Mounted on top surface (380 mm from top‑center point); check valve with inner diameter Φ10 mm for connecting gas sampler |
| 9 | Odor identification port | Covered opening Φ50 mm beside exhaust check valve for odor identification; material: 304 mirror‑finished stainless steel |
| 10 | Timing function | Power‑on/off timing, odor‑evaluation reminder, sampling reminder, sampling timing |
| 11 | Constant‑temperature plate | 2 pieces, 800 mm(L) ×300 mm(W), heated aluminum plate. Capable of heating chamber air from 15 ℃ to 36 ℃ within 30 minutes |
| 12 | Test support | Retractable bracket, stainless steel material; 2000 mm(L) ×1000 mm(W) ×300 mm(H) |
| 13 | Measurement & control system | 6‑inch color touch screen; real‑time monitoring and recording of chamber temperature, time and other control parameters |
| 14 | Safety protection | Temperature alarm and overtime alarm |
| 15 | Power supply | AC 380V, 50Hz, 23A |

The Upper‑Hinge Flip‑Door Slamming Tester simula ...

The electric folding mechanism testing machine for ...

The automatic comprehensive mattress tester is sui ...

The fabric dynamic fatigue testing machine simula ...
Contact Us
contact usGetintouchwithus