TST‑C1003B Yewellkang Compression Set Tester
The Yewellcon compression set tester is used to ...
Sponge Flame retardant Performance Tester is applicable for insulating materials, engineering plastics and other solid combustible material industries.
This device features elegant appearance, convenient operation and reliable performance.
The test equipment complies with the requirements of GB/T 8832-2008、ISO 9772:2001 and GB/T 8333 2008 standards.
It is used to determine the horizontal burning performance of small foam plastic specimens with density less than 250kg/m under small flame conditions in laboratory in accordance with ISO 845:1985, and to evaluate the vertical burning performance of rigid foam plastics under laboratory conditions.
This test equipment complies with the requirements of GB/T 8832 2008、ISO 9772:2001 and GB/T 8333 2008 standards.
| Item | Specification |
|---|---|
| Working Power Supply | 220V AC 50Hz |
| Flame Application Time | 0‑999.9 s (adjustable) |
| After‑flame Time | 0‑999.9 s (adjustable) |
| After‑glow Time | 0‑999.9 s (adjustable) |
| Flame Application Cycles | 0‑9999 times (adjustable) |
| Burning Angle | 0°, 15°, 45° optional |
| Flame Height | 20 mm‑175 mm adjustable |
| Gas Pressure | 0‑0.2 MPa, differential pressure gauge ±300 mm water column |
| Burning Burner | Tube inner diameter: 9.5±0.3 mm, length: 100 mm±10 mm |
| Timing Device | Accurate to 0.5 s |
| Pressure Gauge | Measures up to 200 mm water column, in 5 mm increments |
| Flow Meter | Maximum measuring accuracy ±2% |
1. Before operating this equipment, operators shall carefully read the product operation manual, master safety knowledge for flammable gas handling and take adequate safety precautions. Tests can only be performed after confirming no gas leakage.
2. If gas leakage is detected, stop the test immediately. Do not ignite any flame or switch on power supply. Open doors and windows of equipment and laboratory to vent gas outdoors. For minor leakage, turn on exhaust fan to accelerate removal of flammable gas.
3. Before opening gas source, turn pressure and flow regulating valves to minimum position first. Then open the main valve of gas cylinder, and slowly adjust gas pressure and flow to required values. Excessively high initial pressure flow may drain all liquid inside U tube and cause gas leakage.
4. When switching to different gas types, fit corresponding pressure reducing valve and purge residual gas inside gas pipeline to avoid hazards caused by mixing of different gases.
5. Upon test completion, close gas cylinder valve first. Keep the Bunsen burner burning until residual gas inside pipeline is fully consumed, then close other valves.
6. Frequently inspect sealing performance of gas pipelines and joints. Replace aged pipelines promptly to guarantee operational safety.
7. Lubricate instrument components periodically to prevent jamming caused by insufficient lubrication, which may impair normal operation.